Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
22
3.1.16 Robofon (Message Type j)
Robofon
Example
D6500 Byte Description
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
h j r r l s s s s a a a a a a E E s s s s t
Table 18: Robofon (Message Type j) Byte Description
# Title Description
1 Header Character
(
h
)
Optional. Check with the computer automation software for
compatibility.
2 Message Type j
3-4 Receiver Number
Receiver gateway number from 01 to 99.
5 Line/Group
Number
Line number in the receiver gateway that sent the message.
6-9 Spaces Four spaces.
10-15 Account Number Six digit account number.
16-17 EE Event code.
18-21 Spaces Four spaces.
22 Trailer Character Typically, this is HEX 14.